Before Calling For Service Section 5
5-2
Part Number 000005544 12/09
Safeguard Feature
In addition to standard safety controls, your Manitowoc ice machine features built-in SafeGuards. The ice machine will
stop when conditions arise that would cause major component failure.
GENERAL
The ice machine control board has safety features to
protect the ice machine from severe failures. The ice
machine will stop when conditions arise that would
cause major component failure.
A control board light will flash to indicate which
Safeguard has stopped the ice machine.
Safeguards can be viewed by placing the ICE/OFF/
CLEAN toggle switch in the OFF position.
After 48 hours a Safeguard is automatically erased.
DETERMINING WHICH SAFEGUARD STOPPED THE
ICE MACHINE
Move the ICE/OFF/CLEAN toggle switch to OFF.
If a safeguard has stopped the ice machine, the light
which corresponds to the failure will flash.
SAFEGUARD INDICATOR LIGHTS
During a SafeGuard Mode the corresponding light will
flash continuously.
Example; the “water ok” light on the control board
flashes when the toggle switch is placed in the Off
position. This indicates a loss of water in the reservoir or
a failure of the water sensing switch.
The SafeGuard will remain in memory for 48 hours after
the control is reset with the toggle switch. After 48 hours
the SafeGuard will automatically be erased. If power is
interrupted during the 48 hours, the timing will resume
when power is applied to the ice machine.
Placing the toggle switch in the OFF position:
The corresponding light will flash continuously.
Placing the toggle switch in the ICE position:
The light will de-energize and a start-up sequence will
initiate.
During the first 48 hours after the control board was
reset, the corresponding light will flash anytime the
toggle switch is placed in the OFF position.
SafeGuards
1. No Water - The water sensor switch opens for more
than 20 seconds during the freeze cycle.
2. No Ice Production - The damper door (HES1) fails to
open and close at least once during the first 8
minutes of compressor run time.
or
The damper door fails to open and close at least
once every 90 seconds during the freeze cycle.
RESET PROCEDURE
1. Move the ICE/OFF/CLEAN toggle switch to OFF
and then back to ICE.
A. If a safeguard feature has stopped the ice
machine, it will restart after a short delay.
Proceed to step 2.
B. If the ice machine does not restart, refer to “Ice
Machine Does Not Operate” in section 5.
2. Allow the ice machine to run to determine if the
problem still exists.
A. If the ice machine continues to run, the condition
has corrected itself. Allow the ice machine to
continue running.
B. If the ice machine stops again, the problem still
exists.