Ice Machine Operation Section 3
3-4
Part Number 000005544 12/09
Removal from Service/Winterization
GENERAL
Special precautions must be taken if the ice machine
head section is to be removed from service for an
extended period of time or exposed to ambient
temperatures of 32°F (0°C) or below.
Follow the procedure below.
1. Disconnect the electrical power at the circuit breaker
or the electric service switch.
2. Turn off the water supply.
3. Disconnect and drain the incoming ice-making water
line at the rear of the ice machine.
4. Disconnect drain tubing (from the inlet to dump
valve) and drain water into container and discard.
5. Make sure water is not trapped in any of the water
lines, drain lines, distribution tubes, etc.
!
Caution
If water is allowed to remain in the ice machine in
freezing temperatures, severe damage to some
components could result. Damage of this nature is
not covered by the warranty.