Section 5 Before Calling For Service
Part Number 000005544 12/09 5-3
SafeGuard Modes
NO WATER
During the Freeze cycle if the water sensing switch
opens or remains open for more than 20 continuous
seconds,
1. The ice machine will de-energize the compressor
and gear motor immediately
2. Continuously flash the control board water OK light
3. Initiate a 15 minute Standby Mode
After the 15 minute standby the ice machine will check
the status of the water level sensor.
WATER LEVEL SENSOR CLOSED:
The ice machine will initiate a startup sequence.
WATER LEVEL SENSOR OPEN:
The ice machine will wait for the water level sensor to
close.
INDICATOR LIGHT
Before 48 hours have elapsed:
After a Standby Mode has been initiated the water level
light will flash anytime the toggle switch is placed in the
OFF position.
After 48 hours have elapsed:
The SafeGuard will be automatically erased from
memory and the water level will not flash.
No Water SafeGuard Checklist
Possible Problem List Corrective Action List
No water Restore water supply.
Water float valve screen blocked Clean screen.
Water float valve improperly adjusted Adjust valve (see Water level check).
Dump valve leaking Repair or replace dump valve.
Water sensing switch disconnected or removed Connect or correctly position sensor