Manitowoc MULTIPLEX 11M Specifications Page 80

  • Download
  • Add to my manuals
  • Print
  • Page
    / 236
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 79
80 Part Number STH12 9/10
PGM Switch
Used to enter and exit programming modes.
Press PGM Switch F000 will display
Press and hold Carb A switch — Display will
indicate Water Bath Temperature
Press and hold Circ A switch — Display will
indicate Discharge Temperature
Press and hold Circ B switch — Display will
indicate Suction Temperature
Press PGM Switch P000 will display
Press and hold Carb A switch — Display will
indicate Water Pressure
Press and hold Carb B switch — Display will
indicate CO2 Pressure
Press and hold PGM switch for 3 seconds to save
settings and exit program mode.
Program Mode 1
To enter, press and hold switch for 3 seconds.
0001 will display indicating Mode 1
Wait 3 seconds — C000 will display
Press and hold Carb A switch — Display will
indicate one of the following:
CA00 — Low and High Probes are open
(carbonator motor is energized)
CA11 — Low and High Probes are closed
(carbonator motor is de-energized)
CA01 — Low Probe closed (Motor will still be
on)