Power Interruption
During a power interruption the control will resume
from the point of interruption when power is reapplied
and the time delay expires. Any switches/components
that were energized when power was interrupted will
be energized when power is reapplied.
Error Codes
E1 = Low Water Supply Pressure
E2 = Low CO
2
Pressure
E3 = Low Water Level - Water Bath
E4 = High Water Bath Temperature
E5 = High Water Supply Pressure
E6 = High Refrigeration Temperature
E7 = High Ice Bank Size (Probe Sensor 2)
E8 = Long Carb A Run Time
E9 = Long Carb B Run Time
NOTE: Shorted Transducer = "----"
Open Transducer = "===="
Error codes will display until corrected.