Manitowoc QD0672C Specifications Page 35

  • Download
  • Add to my manuals
  • Print
  • Page
    / 54
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 34
Section 3 Ice Machine Operation
Part No. 80-1175-3, 6/03 3-3
HARVEST SEQUENCE
5. Water Purge
The water pump continues to run, and the water dump
valve energizes for 45 seconds to purge the water in the
sump trough. The water fill valve energizes (turns on) for
the last 15 seconds of the 45-second water purge.
After the 45 second water purge, the water fill valve,
water pump and dump valve de-energize. (Refer to
“Water Purge Adjustment” for details.)
The cool vapor solenoid valve also opens at the
beginning of the water purge to divert refrigerant gas into
the evaporator.
When the refrigerant pressure is low enough to open the
fan cycling pressure control* the condenser fan motor
stops.
* The Q0600C ice machine does not use a fan cycle
control, therefore the condenser fan motor will
continue to run in the harvest cycle.
6. Harvest
The cool vapor solenoid valve remains open and the
refrigerant gas warms the evaporator causing the cubes
to slide, as a sheet, off the evaporator and into the
storage bin. The sliding sheet of cubes swings the water
curtain out, opening the bin switch.
The momentary opening and re-closing of the bin switch
terminates the harvest sequence and returns the ice
machine to the freeze sequence (steps 3-4).
AUTOMATIC SHUT-OFF
7. Automatic Shut-Off
Ice Machine Section: When the storage bin is full at the
end of a harvest sequence, the sheet of cubes fails to
clear the water curtain and will hold it open. After the
water curtain is held open for 7 seconds, the ice
machine shuts off. The ice machine remains off for 3
minutes before it can automatically restart.
CVD Condensing Unit: The liquid line solenoid valve
closes, allowing the refrigeration system to pump down.
when the refrigerant pressure is low enough to open the
fan cycling pressure control* the condenser fan motor
stops. When the refrigerant pressure is low enough to
open the low pressure control, the contactor coil is de-
energized and the compressor stops.
The ice machine remains off until enough ice has been
removed from the storage bin to allow the ice to fall clear
of the water curtain. As the water curtain swings back to
the operating position, the bin switch re-closes and the
ice machine restarts (steps 1 - 2), provided the 3 minute
delay period is complete.
* The Q0600C ice machine does not use a fan cycle
control, therefore the condenser fan motor will
energize and de-energize with the compressor.
Page view 34
1 2 ... 30 31 32 33 34 35 36 37 38 39 40 ... 53 54

Comments to this Manuals

No comments