Q Model AuCS® Accessory (Automatic Cleaning System) Installation Owner/Operator Use and Care Guide This manual covers instal
Installation Instructions Section 22-2 Location/Mounting CAUTION Do not install in an area where the air temperature falls below 35F or exceeds
Section 2 Installation Instructions2-3 BASE OF ICE MACHINE Height and Distance Requirements SV1639GNO! TOO HIGH 2” NO! TOO LOW BOX BASE OR BOX
Installation Instructions Section 22-4 Connection to Ice Machine GENERAL Parts Identification PVC CONDUIT FITTING (A) INSTALLATION ½” PVC CONDU
Section 2 Installation Instructions2-5 Connection to Ice Machine (cont.) Q200 Q450 Q600 Q800 Q1000 Q1300 Q1800 Q320 Q420 1-1/8” DIAMETE
Installation Instructions Section 22-6 Connection to Ice Machine (cont.) PVC CONDUIT CONNECTION (NOT SUPPLIED) Connect the ½” PVC conduit from th
Section 2 Installation Instructions2-7 Connection to Ice Machine (cont.) WATER INLET VALVE ACCESS HOLE WATER INLET BARBED FITTING SV1641GVinyl Tu
Installation Instructions Section 22-8 Connection to Ice Machine (cont.) MODULAR WIRE CONNECTION Insert the low voltage modular wire through the ½
Section 2 Installation Instructions2-9 Connection to Ice Machine (cont.) VINYL TUBING CONNECTION 1. Insert the tubing into the ½” conduit from th
Installation Instructions Section 22-10 Determine Type Of Solution Needed CAUTION Use only Manitowoc-approved Ice Machine Cleaner (part number 9
Section 2 Installation Instructions2-11 Changing Solution Type CAUTION Do not mix Cleaner and Sanitizer solutions together. It is a violation of
Safety Notices When installing or using the Q Model AuCS® accessory, be sure to pay close attention to the safety notices in this manual. Disregarding
Installation Instructions Section 22-12 Setting Frequency Of Cleanings The AuCSis factory-set to clean (or sanitize) the ice machine approximatel
Section 3 Ice Machine Operation3-1 Section 3 Ice Machine Operation Automatic Operation The following occurs when the toggle switch is in the ICE
Ice Machine Operation Section 33-2 Changing Switch Position During Automatic Operation If the toggle switch is moved to OFF prior to the pump disp
Complete the following and retain for your records: Distributor/Dealer ________________________________________________________
MANITOWOC ICE, INC. 2110 South 26th Street P.O. Box 1720 Manitowoc, WI 54221-1720 Phone: (920) 682-0161 Fax: (920) 683-7585 Web Site - www.mani
Table of Contentsi Table of Contents Section 1 - General Information Freight Damage and Claims Procedure...
Table of Contents ii THIS PAGE INTENTIONALLY LEFT BLANK
Section 1 General Information1-1 Section 1 General Information Freight Damage and Claims Procedures 1. Shortages Check the number of cartons deli
General Information Section 11-2 Owner Warranty Registration Card GENERAL The packet containing this manual also includes warranty information. Wa
Section 1 General Information1-3 Component Location and Identification MOUNTING SLOTS Component Location/Identification DISPENSING PUMPMODU
General Information Section 11-4 THIS PAGE INTENTIONALLY LEFT BLANK
Section 2 Installation Instructions2-1 Section 2 Installation Instructions General These instructions are provided to assist the qualified instal